* With the <code>MODE SELECTOR</code> knob in the <code>COEFF</code>, <code>MINION</code>, <code>IC</code>, <code>OP</code> or <code>HALT</code> positions, the panel meter displays the numerical value patched into the <code>u</code> socket in the <code>OUTPUT JACKS</code> section in the unit range -1 to 1. This allows monitoring any value in a program by connecting any socket on the patch panel with the <code>U</code> socket. In particular, it allows setting the values of coefficient potentiometers by connecting any potentiometer's output to the <code>U</code> socket and turning the respective potentiometer knob until the panel meter displays the desired value. | * With the <code>MODE SELECTOR</code> knob in the <code>COEFF</code>, <code>MINION</code>, <code>IC</code>, <code>OP</code> or <code>HALT</code> positions, the panel meter displays the numerical value patched into the <code>u</code> socket in the <code>OUTPUT JACKS</code> section in the unit range -1 to 1. This allows monitoring any value in a program by connecting any socket on the patch panel with the <code>U</code> socket. In particular, it allows setting the values of coefficient potentiometers by connecting any potentiometer's output to the <code>U</code> socket and turning the respective potentiometer knob until the panel meter displays the desired value. | ||
− | * With the <code>MODE SELECTOR</code> knob in the <code>REP</code> or <code>REPF</code> positions, the current <code>OP TIME</code> value is shown. | + | * With the <code>MODE SELECTOR</code> knob in the <code>REP</code> or <code>REPF</code> positions, the current <code>OP TIME</code> value is shown. The OP-TIME can be changed using the <code>OP-TIME</code> potentiometer. In <code>REP</code> (repeat) mode, <code>OP TIME</code> values are shown in the 0 to 10 second range. In <code>REPF</code> (repeat fast) mode, <code>OP TIME</code> values are shown in the 0 to 100 millisecond range. |
[[Category:Components of The Analog Thing]] | [[Category:Components of The Analog Thing]] |
Revision as of 04:55, 30 August 2021
The panel meter is the LCD display unit located in the lower right on the upper PCB.
Usage
The panel meter is used in two different modes, depending on the position of the MODE SELECTOR
knob:
- With the
MODE SELECTOR
knob in theCOEFF
,MINION
,IC
,OP
orHALT
positions, the panel meter displays the numerical value patched into theu
socket in theOUTPUT JACKS
section in the unit range -1 to 1. This allows monitoring any value in a program by connecting any socket on the patch panel with theU
socket. In particular, it allows setting the values of coefficient potentiometers by connecting any potentiometer's output to theU
socket and turning the respective potentiometer knob until the panel meter displays the desired value. - With the
MODE SELECTOR
knob in theREP
orREPF
positions, the currentOP TIME
value is shown. The OP-TIME can be changed using theOP-TIME
potentiometer. InREP
(repeat) mode,OP TIME
values are shown in the 0 to 10 second range. InREPF
(repeat fast) mode,OP TIME
values are shown in the 0 to 100 millisecond range.